  • Dimensions:

  • Overall:
  • 1420(w) x 750(h) x 720(d) mm
  • Workspace:
  • 800(w) x 480(h) x 500(d) mm
  • Interlock:
  • 120(w) x 260(h) x 280(d) mm
  • Capacity:

  • Maximum: 610 plates
  • Interlock: 45 plates
  • Other:

  • Standard Cycle: 45 seconds
  • Weight: 100 Kg

Downloads/Links:

Hypoxic Workstation

The Ruskinn Invivo2 400 has been designed to meet the changing needs of medical researchers.

With a spacious 500 plate working capacity, the Invivo2 400 allows the transfer of samples and access to the environment without affecting stability. For researchers trying to study hypoxia the Invivo2 400 provides a precise oxygen control system in 0.1 % increments, via the gas mixing system, with the benefit that cells are not stressed by the environment fluctuations caused by opening the door on more conventional three-gas incubation systems.

The Gas Mixing System provides accurate control over O2 (0.1% - 20% in 0.1% increments), CO2 indication (0% - 12% in 1% increments) and H2 (0% - 10% in 1% increments) components of the mix with integral oxygen sensor and calibration port.

Our experience shows that once a research centre invests in a Ruskinn Invivo2 workstation many different scientists use the system for all aspects of cell research. For that reason we have equipped the Invivo2 400 with an optional removable front to allow access for equipment and cleaning between different experiments. The interlock on the Invivo2 400 is larger and consequently gives greater flexibility to larger more diverse research facilities.

Features and Benefits

  • 45 seconds Interlock Cycle Time for rapid transfer of up to 20 plates
  • Manual Interlock Outer Door Operation for simple front loading access
  • Minimum / Maximum Incubation Temperature - ambient +5oC to 45oC
  • Up to 4 Gas Operation; H2/N2, CO2, N2, Air for low gas consumption and running costs
  • Workstation Fabrication is solvent bonded acrylic for optimum cell conditions

Standard Accessories

  • Energy Saving Fluorescent Lamp for perfect illumination
  • Foot Operated High Intensity Halogen Lamp for close inspection of samples
  • Automated Humidity Control for optimum cell conditions
  • Gas Low Alarms to alert operator of gas requirements
  • Ezee SleevesTM port entry system for quick bare hand access
  • Detox for optimum workstation environment
  • 3 Petri Dish Holders for colour coded plate storage
  • 1 wire Rack for storage of up to 30 plates
  • Removable Front for easy loading and cleaning
  • Internal Mains Socket for powering small accessories
  • Single Plate Entry System to allow the direct introduction of individual plates with out the interlock cycle

Optional Accessories

  • Ultrasonic Humidity Control for improved cell conditions
  • Cable Gland Port to allow the passage of cables through the workstation wall without altering internal conditions
  • Vacuum Line Port to allow the attachment of a vacuum line used to remove waste media from plates without removing them from the anaerobic conditions inside the workstation
  • Trolley to store workstation where bench space is not available
  • Data Logging Connection allows the user to monitor the temperature of the workstation via a PC
  • Power Failure Back Up System maintains the anaerobic environment inside workstation if there is a mains power failure